Input
|
Phase
Rated Voltage
Voltage Range
Frequency Range
Power Factor
Current THDi
Current THDi
Bypass Voltage Range
Bypass Voltage Range
Bypass Voltage Range
Bypass Voltage Range
FCO Range
Generator Input
|
1Phase 2 Wires + Ground or3 phase 4 wires+ ground
380/400/415VAC or 220/230/240VAC
208-478Vc or 120vac-276vac
45Hz-55Hz / 55Hz-66Hz
>0.99
<3% at (100% linear load )
<5% at (100% non- linear load )
220VAC Max : voltage; 10%, 15%, 20% or 25% default : 25%
230VAC Max : voltage; 10%, 15%, 25% default : 20%
240VAC Max : voltage; 10%, or 15% default : 15%
Min:20%,30%,or45%, default : 45%
Same as the bypass
Support
|
Output
|
Phase
Rated Voltage
Power Factor
?Voltage Regulation
Frequency - Utility Mode
Frequency - Battery Mode
Crest Factor
THD
THD
Wave Form
|
1Phase 2 Wires + Ground Dd
22/230/240VAC
0.9
?+/- 1%
±1%, ±2%, ±4%, ±5%, ±10% of the Frequency (optianal)
(50Hz ±1%) Hz
3:1
< 2% with Linear Load
< 5% with non Linear Load
Pure Sine Wave
|
Battery
|
Voltage
Backup Time
Backup Time
Recharge Time to 90%
Charging Current
Battery Socket
|
Standard 192Vdc; Optional voltage: 216/240 Vdc
Full load ≥ 2 min(Standard) Long time unit depends on the capacity of external batteries
Estimated remaining time display on LCD
3 Hours(90% after fully discharged)
Maximum Current 10A; charge current can be set according to battery capacity installed.
Anderson Like PowerPole Modular Connectors
|
Transfer Time
|
|
Utility to Battery; 0ms, Utility to Bypass <4ms
|
Protection?
|
Overload - AC Mode
Overload - Batt. Mode
Overload - Bypass Mode
Short Circuit
Overheat
Battery Low
Self-Diagnostics
EPO
Battery
Noise Suppression
|
105%~1H, 110%~125% : 10mins, 125%~150% : 1 min, ≥150% : 200ms < then tranfer to bypass
105%~1H, 110%~125% : 10mins, 125%~150% : 1 min, ≥150% : 200ms < then shutdown UPS completely
40A(Input Breaker)
Hold Whole System
Line mode; Switch to Bypass; Backup Mode Mode, shutdown UPS immediately
Alarm and Switch off
Upon Power On and Software Control
Shutdown UPS immediately
Advanced Battery Management
Complies with EN60664-1
|
Alarm
|
Audible & Visual
|
Line Failure, Battery Low, Overload, System Fault
|
Display
|
Status LED & LCD
Reading on the LCD
|
Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery bad, Overload & UPS Fault
Input Voltage, Input Frequency,Output Voltage, Output Frequency, Load percentage,
Battery Voltage, Inner Temperature & Remaining Battery Backup Time
|
Physical
|
Input Connection
Output Connection
External Battery Connection
|
Hardwire
Hardwire & IEC320c13-10Ax2
Anderson like PowerPole Modular connectors
|
Communication Interface
|
|
USB , dry contract ,parellel , communication solt
|
Environment
|
??Operating Temperature
Storage Temperature
Humidity
Altitude
Noise
|
0 °C - 40 ° C
25°C ~ + 55°C
0-95% non-condensing
<1500 m. (derating while > 1500m)
<55 dB (at 1 meter)
|
Safety Conformance
|
|
Complies with EN60664-1
|